RESIDENTIAL ROOFTOP SOLAR · BENGALURUENGINEERED FOR INDEPENDENT HOMES & VILLAS

01 / RESIDENTIAL ARCHITECTURE

Engineered for your terrace.
Sized for a 5x+ lifetime return.

We design domestic solar installations around your monthly consumption in kWh, usable unshaded roof area and clean structural integration — with realistic Bengaluru generation of 3.8 to 4.0 units per kWp per day and full DCR subsidy vs Non-DCR transparency.

3 kWp OUTPUT
~360 – 400 units / month
GOVT SUBSIDY
Up to ₹78,000 (DCR Tier)
LIFETIME ROI
4.5x – 5.5x Return Multiple
FIG R-01 / DOMESTIC TERRACE INTEGRATIONJALAHALLI · BENGALURU
Actual Aryama residential rooftop solar array in Jalahalli, Bengaluru
Actual Aryama Installation · Jalahalli, Bengaluru
01 / USABLE TERRACE02 / SHADOW ENVELOPE03 / CLEAN ROUTING

ARCHITECTURAL CAD SIMULATION · CONTEMPORARY BENGALURU VILLA

From raw roof geometry to synchronised building power.

Scroll through the four engineering stages below or switch building topologies inside the CAD viewport. The procedural 3D model responds directly to your scroll position · illustrating LiDAR scanning, BOM staging, structural mounting and live solar-to-AC conversion.

01 / LIDAR ROOF SCAN
ARRAY ORIENTATION180.0° SOUTH
STRUCTURE GEOMETRY13.0° OPTIMUM
ELECTRICAL INTERFACERESIDENTIAL DB / 230V-415V
TELEMETRY STATUSMAPPING SHADOW CORRIDORS
01STAGE 01 / TERRACE LIDAR & SHADOW ENVELOPE

Site visit, parapet shadow study & RCC slab verification

We map your usable terrace polygon at 12.97° N, logging overhead water tank shadows, staircase mumty height, skylight clearances and existing distribution board termination.

02STAGE 02 / EXPLODED HARDWARE STAGING

Hot-dip galvanised structures, monocrystalline modules & protection

Every component · elevated HDG mounting pedestals, wind-rated rails, high-efficiency monocrystalline PV modules and DC/AC surge protection · is staged to match your terrace geometry.

03STAGE 03 / ARCHITECTURAL MOUNTING & CONDUIT ROUTING

Non-destructive anchoring & concealed vertical shaft routing

Structures lock onto the terrace with waterproofed chemical anchoring, preserving terrace access below while UV-stabilised DC conduits trace neatly down the building shaft.

04STAGE 04 / BIDIRECTIONAL METER & HOME POWER FLOW

Solar harvest, inverter conversion & household priority feed

Collimated sunlight excites the array, sending DC power to the wall-mounted inverter. Converted AC electricity powers home loads first and exports surplus through the bidirectional meter.

02 / HOMEOWNER ENGINEERING GUIDE

What determines the right system for a Bengaluru home.

Before choosing equipment brands, three physical, financial and electrical variables govern how a residential solar plant performs over 25 years.

CHAPTER 01 / DEMAND & SUBSIDY ARCHITECTURE

Monthly kWh sizing & DCR vs Non-DCR module selection

Balancing PM Surya Ghar subsidy eligibility against open-market module pricing.

A 3 kWp residential system in Bengaluru generates ~360 to 400 units per month (at 3.8 to 4.0 units/kWp/day). Homeowners can opt for DCR (Domestic Content Requirement) modules (~₹70,000/kWp + GST indicative ceiling, eligible for up to ₹78,000 direct subsidy) or Non-DCR modules (~₹55,000–₹60,000/kWp + GST indicative band) for larger custom villa arrays.

  • 12-month kWh seasonal consumption profile audit
  • Direct ₹78,000 PM Surya Ghar subsidy guidance on DCR plants (3 kWp+)
  • Actual system outlay is typically lower and determined post site audit
CHAPTER 02 / USABLE TERRACE GEOMETRY

Shadow-free area & elevated walkable pergolas

Your terrace remains an architectural living space first.

Overhead water tanks, staircase mumties, neighbouring buildings and parapet walls cast shifting shadow corridors across the year. As executed in our Malleshwaram and Virupakshapura installations, we elevate hot-dip galvanised structures so your family retains full terrace floor access below.

  • 365-day solar azimuth & parapet shadow allowance
  • High-clearance elevated pergola options to preserve terrace floor
  • Dedicated maintenance & module-washing access corridors
CHAPTER 03 / STRUCTURAL & ELECTRICAL CRAFTSMANSHIP

Non-destructive anchoring & precision ACDB/DCDB trunking

Engineered for monsoon downpours, wind uplift and electrical safety.

Structures are anchored with chemical fasteners and multi-stage waterproofing seals. Inside your utility shaft, DC and AC cables terminate into dedicated surge-protected distribution boxes with neat horizontal PVC trunking — as demonstrated in our Banashankari residential installations.

  • Hot-dip galvanised corrosion-resistant mounting structures
  • Non-destructive or sealed chemical anchor pedestals
  • Dedicated ACDB/DCDB protection with dual earthing & lightning arrestor
Elevated walkable solar pergola in Malleshwaram, Bengaluru
STRUCTURAL EXECUTION · MALLESHWARAM

Elevated Walkable Terrace Pergola

High-clearance HDG structure keeping the entire terrace floor open below, complete with lightning protection.

Clean inverter and ACDB/DCDB termination in Banashankari, Bengaluru
ELECTRICAL EXECUTION · BANASHANKARI

Inverter, ACDB/DCDB & Concealed Trunking

Clean wall termination with dedicated surge protection enclosures and enclosed PVC cable raceways.

03 / HOME SOLAR SIZING & ROOF CALCULATOR

Calculate your exact system size from your monthly kWh units.

Enter your average monthly electricity units from your BESCOM bill to instantly calculate your recommended kWp capacity and unshaded roof area needed.

INPUT YOUR MONTHLY UNITS BELOW:Enter your average monthly BESCOM consumption in kWh (units) to check your recommended system size.
ENTER UNITS

Check your BESCOM bill and enter the monthly consumption in kWh (units).

kWh / month
90%

Most homeowners size their plant to cover 85% to 100% of monthly kWh.

OPTIONAL
sq. ft.
RECOMMENDED SIZING SPECIFICATION3.8 – 4.0 UNITS/kWp/DAY
RECOMMENDED SOLAR SYSTEM CAPACITY
3.5 to 4.0 kWp

To generate ~432 units/month (90% of 480 kWh)

ESTIMATED MONTHLY GENERATION410 to 468 units / moAt 3.9 units/kWp/day
UNSHADED ROOF REQUIRED335 to 380 sq. ft.Includes maintenance corridors (~95 sq.ft/kWp)
Your entered terrace area (450 sq. ft.) can easily fit up to ~4.7 kWp.

03 / RESIDENTIAL kWh CALCULATOR, SUBSIDY & 25-YEAR ROI GRAPH

Input your monthly kWh units, compare subsidy & chart your 25-year return.

Enter your monthly electricity consumption from your BESCOM bill. Calibrated to Bengaluru irradiance (3.8 to 4.0 units per kWp per day). Compare DCR subsidy-eligible modules against open-market Non-DCR modules, inspect your breakeven curve and track your lifetime carbon offset.

INPUT YOUR VALUES BELOW:Enter your monthly electricity consumption in kWh (units) or adjust system capacity (kWp). Select DCR (with subsidy) vs Non-DCR (without subsidy) to generate your live investment graph.
PRIMARY INPUT

Check your BESCOM electricity bill and enter your average monthly consumption in kWh (units).

kWh / month
Recommended system size: 3.5 kWpUnshaded roof needed: 335 sq. ft.
PRICING TIER

DCR modules qualify for MNRE / PM Surya Ghar subsidy. Non-DCR modules offer lower base hardware outlay for open-market or commercial installations.

₹7.00 / unit

Default ₹7.00/unit for residential slabs; adjust to match your BESCOM tariff category.

*PROFESSIONAL PRICING NOTE: Reference bands of ~₹70,000/kWp + GST (DCR) and ~₹55,000–₹60,000/kWp + GST (Non-DCR) are upper indicative benchmarks. Actual negotiated project pricing is typically lower and depends site-to-site on structural elevation height, hot-dip galvanised steel tonnage, DC/AC cable run length and inverter topology.
INDICATIVE INVESTMENT, ROI & CARBON LEDGER4.8x LIFETIME ROI
INDICATIVE GROSS OUTLAY (+GST)₹2.39 LakhsDCR @ ~₹70k/kWp + 13.8% eff. GST
DIRECT GOVT SUBSIDY- ₹78,000PM Surya Ghar DCR Benefit
EFFECTIVE NET INVESTMENT₹1.61 LakhsPayback in ~4.4 Years
25-YEAR CUMULATIVE ELECTRICITY SAVINGS
₹8.82 Lakhs Saved

Generates ~360 units/mo · Saves ~₹2,520/mo (~₹30,240/yr in Year 1 with 3% annual tariff escalation)

RETURN MULTIPLE5.4xon net outlay
INVESTMENT VS. CUMULATIVE SAVINGS TRAJECTORY (₹ LAKHS)BREAKEVEN: YEAR 4.4
₹1.61L
Net Cost
₹1.60L
Year 5
₹3.46L
Year 10
₹5.62L
Year 15
₹8.82L
Year 25
CARBON FOOTPRINT & ENVIRONMENTAL IMPACT (INDIAN GRID: 0.82 tCO₂/MWh)
88.5 Tonnes CO₂3.54 Tonnes CO₂ avoided / year

Total carbon dioxide emissions prevented over 25 years

1,420 Mature Trees25-year forestry equivalent

Equal to planting & growing mature trees absorbing CO₂ for 25 years

38 Petrol Cars Off-Road~5.1 Lakh km petrol driving offset

Equivalent passenger cars removed from Bengaluru roads for a year

Send this exact system & ROI estimate on WhatsApp
05 / SCHEDULE A HOME ASSESSMENTARYAMA · RESIDENTIAL SOLAR

Verify on your terrace

Book a residential site & shadow assessment.

Share your neighbourhood in Bengaluru, your monthly kWh consumption from your BESCOM bill and whether you prefer a DCR subsidy system or a custom Non-DCR installation.

DIRECT TELEPHONE+91 86600 30997
WHATSAPP ENQUIRIESwa.me/918660030997 ↗
HEADQUARTERS

Abhinand Gardenia, Manjunath Nagar, Ankappa Layout, Uttarahalli, Bengaluru 560061

Verified partnerships

Call +91 86600 30997WhatsApp